Description of UL NOVEC1230 contianer
-- Attributes of Welded Steel TPED series cylinders
Material |
P355M |
|
Carbon: |
≤0.14% |
|
Manganese: |
≤1.60% |
|
Silicon: |
≤0.50% |
|
Phosphorus: |
≤0.025% |
|
Sulphur: |
≤0.010% |
|
Nominal Working Pressure |
42 bar ( 609 psi ) |
|
Pneumatic Test Pressure |
63 bar ( 914 psi ) |
|
Burst Test Pressure |
≥ 126 bar ( 1827 psi ) |
|
Work Temperature |
-20 °C ~ 65 °C |
|
Paint Specification |
Red Polyester Powder Coated |
|
Certification |
TPED |
-- FK-5-1-12 Welded Container Assembly Details (TPED Container)
Cylinder with Valve Assembly Part No. |
Container Assembly Type |
Nominal Working Pressure (bar) |
Nominal Cylinder Volume (L) |
Fill Capacity (kg) |
Outlet Size (mm) |
Empty Weight (kg) |
|
Min. |
Max. |
||||||
813.101.0135 |
AG5112SPA-16.6 |
25 |
16.6 |
8.0 |
18.4 |
33 |
21 |
813.101.0145 |
AG5112SPA-28.3 |
28.3 |
13.6 |
31.4 |
33 |
29 |
|
813.101.0215 |
AG5112SPA-30 |
30 |
14.4 |
33.3 |
33 |
26.3 |
|
813.101.0155 |
AG5112SPA-40 |
40 |
19.2 |
44.4 |
33 |
37 |
|
813.101.0165 |
AG5112SPA-50 |
50 |
24.0 |
55.5 |
33 |
42 |
|
813.101.0175 |
AG5112SPA-60 |
60 |
28.8 |
66.6 |
33 |
47 |
|
813.101.0185 |
AG5112SPA-70 |
70 |
60 |
77.7 |
49 |
59 |
|
813.101.0195 |
AG5112SPA-80 |
80 |
60 |
88.8 |
49 |
64 |
|
813.101.0196 |
AG5112SPA-90 |
90 |
60 |
99.9 |
49 |
73 |
|
813.101.0216 |
AG5112SPA-100 |
100 |
60 |
111 |
49 |
78 |
|
813.101.0226 |
AG5112SPA-120 |
120 |
60 |
133.2 |
49 |
89 |
|
813.101.0296 |
AG5112SPA-142 |
142 |
68.2 |
157.6 |
49 |
108 |
|
813.101.0236 |
AG5112SPA-150 |
150 |
72.0 |
166.5 |
49 |
105 |
|
813.101.0246 |
AG5112SPA-160 |
160 |
76.8 |
177.6 |
49 |
104 |
|
813.101.0256 |
AG5112SPA-170 |
170 |
81.6 |
188.7 |
49 |
139 |
|
813.101.0266 |
AG5112SPA-180 |
180 |
86.4 |
199.8 |
49 |
144 |
|
813.101.0137 |
AG5112SPA-16.6 |
42 |
16.6 |
8.0 |
18.4 |
33 |
21 |
813.101.0147 |
AG5112SPA-28.3 |
28.3 |
13.6 |
31.4 |
33 |
29 |
|
813.101.0157 |
AG5112SPA-40 |
40 |
19.2 |
44.4 |
33 |
37 |
|
813.101.0167 |
AG5112SPA-50 |
50 |
24.0 |
55.5 |
33 |
42 |
|
813.101.0177 |
AG5112SPA-60 |
60 |
28.8 |
66.6 |
33 |
47 |
|
813.101.0187 |
AG5112SPA-70 |
70 |
60 |
77.7 |
49 |
59 |
|
813.101.0197 |
AG5112SPA-80 |
80 |
60 |
88.8 |
49 |
64 |
|
813.101.0198 |
AG5112SPA-90 |
90 |
60 |
99.9 |
49 |
73 |
|
813.101.0218 |
AG5112SPA-100 |
100 |
60 |
111 |
49 |
78 |
|
813.101.0228 |
AG5112SPA-120 |
120 |
60 |
133.2 |
49 |
89 |
|
813.101.0298 |
AG5112SPA-142 |
142 |
68.2 |
157.6 |
49 |
108 |
|
813.101.0238 |
AG5112SPA-150 |
150 |
72.0 |
166.5 |
49 |
105 |
|
813.101.0248 |
AG5112SPA-160 |
160 |
76.8 |
177.6 |
49 |
104 |
|
813.101.0258 |
AG5112SPA-170 |
170 |
81.6 |
188.7 |
49 |
108 |
|
813.101.0268 |
AG5112SPA-180 |
180 |
86.4 |
199.8 |
49 |
144 |
Description of UL NOVEC1230 Fire Suppression System
FK-5-1-12 is a clean, safe fire fighting agent for use in total flooding automatic extinguishing systems. It is intended as a long term replacement for Halons, HFCs, and HCFCs, whilst maintaining the excellent fire suppression properties of them, has none of the environmental problems. Storage and distribution requirements are similar to Halon and the majority of system components are identical. However, FK-5-1-12 is not a direct replacement for existing Halon 1301, HFCs and HCFCs installations due to the difference in agent quantity and discharge characteristics. The minimum FK-5-1-12 design concentration for Class A hazard is 4.5%, for Class B hazard is 5.85%, and for Class C hazard is 4.5%.
Components of UL NOVEC1230 Fire Suppression System
No. |
Part Name |
No. |
Part Name |
1 |
Cylinder |
6 |
Valve Outlet Adaptor |
2 |
Mounting Bracket |
7 |
Pilot Hose |
3 |
Fix Steel Channel |
8 |
Discharge Pressure Switch |
4 |
Container Valve |
9 |
Nozzle |
5 |
Electrical Actuator |
|
|
Features of UL NOVEC1230 Fire Suppression System
Very stable behaviour
In less than 10 seconds, a fast extinguishing time with the discharge
High efficiency, low extinguishing concentration
Applicable in occupied areas
Minimum container footprint
After discharge, there is no residue
Electrically unconductive, secure for use in spaces that are inhabited by humans
Zero ozone depleting potential
Application of UL NOVEC1230 Fire Suppression System
Petrochemical Installations |
Gas Turbines |
Steam Turbine Generators |
Railway Traffic Controls |
Power Generation Plants |
Electrical Equipment |
Transformer and Switch Rooms |
Communication Centre |
Printing Facilities |
Food Packaging Facilities |
Packaging Plans |
Control Rooms |
|
|
Packages of UL NOVEC1230 Fire Suppression System
We always pack it with polyfoam firstly and then put it into a wooden case. Sometimes, in order to meet with customers or the safety requirement, we will make a pallet for the goods.